中图分类号:tm341文献标识码:a
文章编号:0258-8013 (2000) 04-0029-06
harmonic-parameter model of synchronous machine
and harmonic load flow study
long yu, chen heng
(department of electrical engineering,southeast university,nanjing 210096, china)
abstract:in this paper, based on[1,2], harmonic-parameter model of synchronous machine is reestablished and new physical interpretation of this model is given;harmonic-parameter models of some other power elements are introduced;corresponding harmonic load flow study program is developed and a lot of computations are undertaken.based on these,it is pointed out that conventional synchronous machine model that does not derive harmonics connot be used in analyzing the actually existing harmonic load flow caused by power element asymmetry;for harmonic load flow caused by power element nonlinearity,this model is also not sufficiently accurate; the new model reestablished in this work is recommended.
key words:power system; harmonics; load flow; synchronous machine; mathematical model
1 引言
随着电力系统中不对称元件和非线性元件的日益增多,电力网络的不对称和谐波污染问题日益严重。另一方面,电力市场上用户对电能质量的要求却日益严格。对电力系统谐波潮流计算的精度要求也就随之日益提高。面对这种要求,出现了若干可用以计算谐波潮流的同步电机模型[1~7]。其中,文[3]中提出的模型主要用于时域仿真;文[4~6]中提出的则失之过简,无法体现同步电机派生的谐波;文[7]中提出的又失之过繁,难以用于大电力系统计算。目前最广泛使用的则是文[4]中由国际大电网会议于80年代初提出的如式(1)所示的模型

(1)
式中 h为谐波次数;x1、x2、x0为同步电机基波正、负、零序电抗。
立论严谨、繁简适中的模型理应为文[1,2]中的研究成果。但因该模型在推演过程中有疏漏,以致最后结果不正确,围绕这一结果所作的物理意义说明也不妥。本文首先重新推导了这一模型,并对其物理意义重新作了说明。然后运用新导得的模型进行了大量谐波潮流计算,并在分析这些潮流计算结果的基础上,作出了相应的结论。
2 对同步电机谐波参数模型的再认识
文[1,2]中导得的对称分量坐标系中同步电机谐波电压、电流相量之间的关系为
i120(h)=y120(h)v120(h)+δi120(h) (2)
式中

(3)

(4)
式中

(5)

(6)

(7)

(8)

(9)* 1)
式(5)~(7)中的矩阵元素则分别为
y12(h-1)=ej2θ0[ydd(h-1)+jyqd(h-1)+jydq(h-1)-yqq(h-1)]/2
(10)
y21(h+1)=e-j2θ0[ydd(h+1)-jyqd(h+1)-jydq(h+1)-yqq(h+1)]/2
(11)
y11(h-1)=[ydd(h-1)+jyqd(h-1)-jydq(h-1)+yqq(h-1)]/2
(12)
y22(h+1)=[ydd(h+1)-jyqd(h+1)+jydq(h+1)+yqq(h+1)]/2
(13)
y00(h)=y00(h) (14)
于是,式(2)可展开为
i1(h)=y11(h-1)v1(h)+δi1(h) (15)*
δi1(h)=y12(h-1)v2(h-2) (16)*
i2(h)=y22(h+1)v2(h)+δi2(h) (17)*
δi2(h)=y21(h+1)v1(h+2) (18)*
i0(h)=y00(h)v0(h) (19)*
这就是在对称分量坐标系中同步电机的谐波参数模型。式中的δi1(h)、δi2(h)可称“解耦-补偿”电流,因运用它们可使同步电机模型在正、负、零序坐标系以及各次谐波之间都相互解耦。
由式(15)~(19)可见*
(1) 如电机端点注入频率为hω的正序电流i1(h)则机端除出现同频率的正序电压v1(h)外,还将出现频率为(h-2)ω的负序电压v2(h-2);
(2) 如电机端点注入频率为hω的负序电流i2(h)则机端除出现同频率的负序电压v2(h)外,还将出现频率为(h+2)ω的正序电压v1(h+2);
(3) 零序电流i0(h)仅对应同频率的零序电压v0(h);
(4) 确定各导纳时的频率之所以与相应电流的频率相差ω是由于这些导纳原属dq0坐标系中参数,dq0坐标系在空间以ω角速度正向旋转;而此处的电流i120(h)、电压v120(h)则为对称分量坐标系中变量,对称分量坐标系在空间不动。
如上所述的电流、电压派生关系还可以图1表示*。而式(15)~(19)所示的同步电机模型还可以图2所示等值电路表示*。

图1 对称分量坐标系中同步电机电流、电压的派生关系
fig.1 derivation of harmonic currents and
voltages of synchronous machine in symmetrical
component reference frame

图2 对称分量坐标系中同步电机的解耦等值电路
fig.2 decoupled equivalent circuits of synchronous
machine in symmetrical component reference frame
3 网络元件的谐波参数模型
由于本文重点在探讨同步电机谐波参数模型,网络中其它电力元件的模型一般从简。
3.1 变压器模型
变压器采用集中阻抗模型rt+jxth,其中xth=hxt。如有必要,还应串联一理想移相器以体现因联结组不同而有的不同相位移。
为简化分析,略去变压器的励磁支路。
3.2 输电线路模型
输电线路谐波参数模型的一般形式为
yz120(h)(vi120(h)-vj120(h))=iij120(h) (20)
ys120(h)vi120(h)=iii120(h) (21)
ys120(h)vj120(h)=ijj120(h) (22)
式中 上标“z”、“s”分别表示输电线π形等值电路中的串联支路和并联支路。
对于对称线路,这一模型不仅各次谐波间解耦,正、负、零序间也相互解耦。但对不对称线路,则应有

(23)

(24)
即正、负、零序间不再解耦。但由于这两个导纳子阵都对角占优,沿用文[9]中的“解耦-补偿”技术,可将式(10)中正序电流的表示式展开为
yz11(h)(vi1(h)-vj1(h))=iij1(h)-δiij1(h)
δiij1(h)=yz12(h)(vi2(h)-vj2(h))+
yz10(h)(vi0(h)-vj0(h))
(25)
ys11(h)vi1(h)=iii1(h)-δiii1(h)
δiii1(h)=ys12(h)vi2(h)+ys10(h)vi0(h)
(26)
ys11(h)vj1(h)=ijj1(h)-δijj1(h)
δijj1(h)=ys12(h)vj2(h)+ys10(h)vj0(h)
(27)
相似地,也可将负序、零序电流的表示式展开。这些就是不对称输电线路的扩展“解耦-补偿”谐波参数模型。而其中的δiij1(h)、δiii1(h)、δijj1(h)则称“解耦-补偿”电流。
3.3 负荷模型
基波频率下的负荷通常以三相功率或电流从而可以三序电流或功率表示。谐波频率下的负荷则往往以三相阻抗表示
zla(h)=f(pa,qa,va,h)
zlb(h)=f(pb,qb,vb,h)
zlc(h)=f(pc,qc,vc,h)
式中 h≥2,pa,pb,pc,qa,qb,qc,va,vb,vc分别为基波频率下的功率和电压。
由三相阻抗可得三相导纳阵ylabc(h)=diag{yla(h),ylb(h),ylc(h)}。将其转换至对称分量坐标系yl120(h)=sylabc(h)s-1,可得相似于式(11)中的ys120(h)满阵。于是可仿照式(23)~(25)得负荷的“解耦-补偿”谐波参数模型如下:
yl11(h)v1(h)=il1(h)-δil1(h)
δil1(h)=yl12(h)v2(h)+yl10(h)v0(h)
(28)
yl22(h)v2(h)=il2(h)-δil2(h)
δil2(h)=yl21(h)v1(h)+yl20(h)v0(h)
(29)
yl00(h)v0(h)=il0(h)-δil0(h)
δil0(h)=yl01(h)v1(h)+yl02(h)v2(h)
(30)
显然,式中的yl11(h),yl22(h),yl00(h)还可并入网络节点导纳阵的相应对角元,而δil1(h),δil2(h),δil0(h)则是负荷模型中的“解耦-补偿”电流。
3.4 静止无功补偿器(svc)模型
取svc为非线性元件的代表。设svc由星形联接的固定电容器和三角形联接的可控电抗器(tcr)并联而成。其tcr部分是一谐波电流源,可由下列步骤求取
。由三序电压可得三相电压;
。由三相电压可得线间电压vab(h),vbc(h),vca(h);
。由线间电压和晶闸管的燃弧角可得线间电流irab(h),irbc(h),irca(h);
。由线间电流irab(h),irbc(h),irca(h)可得三相电流ira(h),irb(h),irc(h);
。由三相电流又可得三序电流ir1(h),ir2(h),ir0(h)。
ir120(h)=sirabc(h) (31)
至于svc的固定电容器部分,则显然为
yc120(h)=diag{yc(h),yc(h),yc(h)} (32)
其中元素也可并入网络节点导纳阵的相应对角元。
4 谐波潮流计算简介
4.1 谐波潮流计算用电力系统模型
谐波潮流计算时应用的电力系统模型由两部分组成,即基波频域模型和谐波频域模型。基波频域模型实际上就是三相潮流计算用模型。它具有如下形式[10]
b′1|v1(1)|δθ1(1)=δp1(1)/|v1(1)| (33)
b″1δ|v1(1)|=δq1(1)/|v1(1)| (34)
y2(1)v2(1)=i2(1) (35)
y0(1)v0(1)=i0(1) (36)
式中 δp1(1),δq1(1)中包含发电机节点、负荷节点、svc(tcr)节点功率和由于线路不对称而有的“解耦-补偿”功率;i2(1)、i0(1)中包含负荷节点、svc(tcr)节点电流和发电机节点“解耦-补偿”电流以及由于线路不对称而有的“解耦-补偿”电流。其它符号则众所周知。
谐波频域模型则为
y1(h)v1(h)=i1(h) (37)
y2(h)v2(h)=i2(h) (38)
y0(h)v0(h)=i0(h) (39)
式中 h≥2;i1(h)、i2(h)、i0(h)中包含发电机节点电流、svc(tcr)节点电流,发电机节点“解耦-补偿”电流以及由于负荷、线路不对称而产生的“解耦-补偿”电流。
4.2 谐波潮流计算主要步骤
谐波潮流计算主要包含两大部分:形成基波和谐波频率下的正、负、零序节点导纳阵及其三角分解;迭代求解基波和谐波频率下的潮流方程。后者主要分以下几步:
。 按式(15)~(19)计算发电机基波频率负序“解耦-补偿”电流和谐波频率正、负、零序电流,其中包括“解耦-补偿”电流;
。 按式(25)~(27)等计算线路基波和谐波频率正、负、零序“解耦-补偿”功率或电流;
。 计算负荷基波频率正、负、零序功率或电流和按式(28)~(30)计算谐波频率正、负、零序“解耦-补偿”电流;
。 按式(31)~(32)计算svc(tcr)基波和谐波频率正、负、零序功率或电流;
。 计算基波频率节点电压-形成δp1(1),δq1(1),并以常规p-q分解法解算式(33)(34); 形成i2(1)、i0(1)并以直接法解算式(35)(36);
。 计算谐波频率节点电压—形成i1(h)、
i2(h)、i0(h)并以直接法解算式(37)~(39);
。 以如下两个判据检验潮流解是否收敛:
基波:max(|δpi1(1)|,|δqi1(1)|)<εp (40)
谐波:max(|δii1(h)|,|δii2(h)|,|δii0(h)|)<εp (41)
5 计算实例
以图3所示的24节点系统作为算例系统。该系统曾用于文[9],此处则又补充了部分发电机参数。为进行比较,还引用式(1)所示发电机模型计算了两种情况,即源于网络元件不对称和源于网络元件非线性的谐波潮流。

图3 24节点算例系统
fig.3 24-bus sample system
由于同步电机的谐波导纳并不因外部网络的不同而有所不同,首先比较了用两种模型计算所得的谐波导纳。设以“简化模型”表示用式(1)所示模型,“新模型”表示用式(15)~(19)所示模型, 则比较结果表明:两种模型的虚部差别不大;但简化模型仅有虚部,而新模型则还有一相对不大的实部。这可能是一般常用简化模型的原因之一。
5.1 算例1——输电线路不对称
设所有输电线路都不对称而所有负荷都对称。在此条件下,由新模型求得的发电机1、6、8“解耦-补偿”电流和节点1、12、17谐波电压如表1、2所示。需指出,在此条件下,无法由简化模型求取这些电流和电压。相似地,设所有负荷都不对称而所有输电线路都对称时,也无法由简化模型求取谐波电流和电压。简言之,由无源支路构成的同步电机简化模型不能用以分析网络中仅电力元件不对称而无其它谐波源的情况。
5.2 算例2——有非线性元件svc(tcr)
设所有输电线路和负荷都对称,但有一svc接于节点25并经升压变压器接于节点14。该svc的tcr部分为一三角形联接、六脉冲晶闸管控制电抗器。取晶闸管燃弧角为30°,因该svc(tcr)的非线性而产生的谐波注入电流如表3所示。显然,这些电流都是六脉冲tcr的特征谐波电流。
表1 某些发电机的“解耦-补偿”电流
tab.1 decoupling-compensation currents of some generators
| | 正 序 | 负 序 |
| h | 发电机 1 | 发电机 6 | 发电机 8 | 发电机 1 | 发电机 6 | 发电机 8 |
| 1 | — | — | — | 0.0305 | 0.0402 | 0.1269 |
| 3 | 0.603 1e-02 | 0.806 6e-02 | 0.261 8e-01 | 0.178 2e-05 | 0.162 9e-05 | 0.339 6e-05 |
| 5 | 0.147 2e-04 | 0.161 6e-04 | 0.257 6e-04 | 0.540 8e-08 | 0.520 6e-08 | 0.871 8e-08 |
| 7 | 0.500 4e-07 | 0.599 3e-07 | 0.134 9e-06 | 0.606 6e-11 | 0.793 8e-11 | 0.424 9e-10 |
| 9 | 0.628 5e-10 | 0.799 9e-10 | 0.576 0e-09 | 0.799 2e-13 | 0.746 1e-13 | 0.719 0e-13 |
| 11 | 0.643 7e-12 | 0.766 7e-12 | 0.126 7e-11 | 0.134 9e-15 | 0.546 4e-16 | 0.266 7e-15 |
| 13 | 0.282 8e-14 | 0.294 0e-14 | 0.393 6e-14 | 0.000 0e+00 | 0.000 0e+00 | 0.000 0e+00 |
表2 某些节点的谐波电压分量
tab.2 harmonic frequency voltage components at some buses
| | 正 序 | 负 序 | 零 序 |
| h | 节点 1 | 节点 12 | 节点 17 | 节点 1 | 节点 12 | 节点 17 | 节点 1 | 节点 12 | 节点 17 |
| 1 | 1.030 0 | 1.003 4 | 1.001 7 | 0.001 2 | 0.008 4 | 0.005 3 | 0.0 | 0.001 5 | 0.002 4 |
| 3 | 0.656e-03 | 0.123e-02 | 0.698e-03 | 0.876e-05 | 0.251e-04 | 0.180e-04 | 0.0 | 0.452e-05 | 0.205e-05 |
| 5 | 0.177e-05 | 0.332e-05 | 0.147e-05 | 0.497e-07 | 0.220e-06 | 0.103e-06 | 0.0 | 0.124e-07 | 0.986e-08 |
| 7 | 0.751e-08 | 0.139e-07 | 0.285e-08 | 0.873e-10 | 0.132e-08 | 0.278e-09 | 0.0 | 0.119e-09 | 0.309e-10 |
| 9 | 0.108e-10 | 0.345e-10 | 0.149e-10 | 0.115e-11 | 0.373e-11 | 0.253e-11 | 0.0 | 0.532e-12 | 0.371e-12 |
| 11 | 0.174e-12 | 0.172e-12 | 0.669e-13 | 0.640e-14 | 0.148e-13 | 0.488e-14 | 0.0 | 0.238e-14 | 0.276e-14 |
| 13 | 0.416e-15 | 0.187e-15 | 0.656e-15 | 0.458e-16 | 0.218e-16 | 0.716e-16 | 0.0 | 0.519e-17 | 0.437e-16 |
表3 svc的谐波注入电流
tab.3 harmonic current injections of svc
| h | 正 序 | 负 序 |
| 5 | 0.000 0e+00 | 0.944 0e-02 |
| 7 | 0.789 7e-02 | 0.000 0e+00 |
| 9 | 0.000 0e+00 | 0.000 0e+00 |
| 11 | 0.000 0e+00 | 0.428 8e-02 |
| 13 | 0.258 1e-02 | 0.000 0e+00 |
对应这些电流,发电机1、6、8的“解耦-补偿”电流和节点1、12、14的谐波电压如表4、5所示。由表可见,这时因所有线路、负荷以及svc (tcr) 本身都三相对称,系统中只有特征谐波电流、电压。
为进行比较,表6中给出了分别用简化模型和新模型求得的各节点五次谐波负序电压。由表可见,靠近谐波源(节点25)的节点谐波电压高于其它节点。由表还可见,计算这些节点的谐波电压时,简化模型带来的误差不大。这可以认为是简化模型适用的范围,但也仅局限于这一范围。因计算发电机端电压的谐波分量时,简化模型就难以满足精度要求。这一现象只能从简化模型本身寻求解释,简言之,就在于它的“无源性”。
表4 某些发电机的"解耦-补偿"电流
tab.4 “decoupling-compensation "currents of some generators
| | 正 序 | 负 序 |
| h | 发电机 1 | 发电机 6 | 发电机 8 | 发电机 1 | 发电机 6 | 发电机 8 |
| 5 | 0.000 0e+00 | 0.000 0e+00 | 0.000 0e+00 | 0.112 4e-03 | 0.135 4e-03 | 0.139 1e-03 |
| 7 | 0.152 5e-03 | 0.180 4e-03 | 0.147 8e-03 | 0.000 0e+00 | 0.000 0e+00 | 0.000 0e+00 |
| 9 | 0.000 0e+00 | 0.000 0e+00 | 0.000 0e+00 | 0.000 0e+00 | 0.000 0e+00 | 0.000 0e+00 |
| 11 | 0.000 0e+00 | 0.000 0e+00 | 0.000 0e+00 | 0.390 5e-04 | 0.492 4e-04 | 0.111 4e-04 |
| 13 | 0.890 1e-04 | 0.989 8e-04 | 0.605 6e-04 | 0.000 0e+00 | 0.000 0e+00 | 0.000 0e+00 |
表5 某些节点的谐波电压分量
tab.5 harmonic frequency voltages at some buses
| | 正 序 | 负 序 |
| h | 节点1 | 节点12 | 节点14 | 节点1 | 节点12 | 节点14 |
| 5 | 0.000e+00 | 0.000e+00 | 0.000e+00 | 0.151e-03 | 0.238e-03 | 0.302e-03 |
| 7 | 0.156e-03 | 0.312e-03 | 0.317e-03 | 0.000e+00 | 0.000e+00 | 0.000e+00 |
| 9 | 0.000e+00 | 0.000e+00 | 0.000e+00 | 0.000e+00 | 0.000e+00 | 0.000e+00 |
| 11 | 0.000e+00 | 0.000e+00 | 0.000e+00 | 0.194e-03 | 0.216e-03 | 0.334e-03 |
| 13 | 0.101e-03 | 0.330e-04 | 0.136e-03 | 0.000e+00 | 0.000e+00 | 0.000e+00 |
表6 不同节点的五次谐波负序电压
tab.6 negative sequence fifth harmonic frequency voltages at dipperent buses
| 节点 | 简 化 | 新 | 节点 | 简 化 | 新 |
| 1 | 0.161e-03 | 0.151e-03 | 14 | 0.302e-03 | 0.302e-03 |
| 2 | 0.161e-03 | 0.151e-03 | 15 | 0.247e-03 | 0.246e-03 |
| 3 | 0.161e-03 | 0.151e-03 | 16 | 0.292e-03 | 0.296e-03 |
| 4 | 0.184e-03 | 0.184e-03 | 17 | 0.279e-03 | 0.279e-03 |
| 5 | 0.184e-03 | 0.184e-03 | 18 | 0.265e-03 | 0.269e-03 |
| 6 | 0.185e-03 | 0.179e-03 | 19 | 0.276e-03 | 0.276e-03 |
| 7 | 0.185e-03 | 0.179e-03 | 20 | 0.224e-03 | 0.224e-03 |
| 8 | 0.141e-03 | 0.147e-03 | 21 | 0.200e-03 | 0.208e-03 |
| 9 | 0.259e-03 | 0.257e-03 | 22 | 0.237e-03 | 0.246e-03 |
| 10 | 0.269e-03 | 0.268e-03 | 23 | 0.233e-03 | 0.241e-03 |
| 11 | 0.281e-03 | 0.279e-03 | 24 | 0.194e-03 | 0.201e-03 |
| 12 | 0.229e-03 | 0.238e-03 | 25 | 0.119e-02 | 0.119e-02 |
| 13 | 0.268e-03 | 0.268e-03 |
6 结论
本文中重建了立论严谨、繁简适中,用于电力系统谐波潮流计算分析的同步电机模型。
与简化的“无源”模型不同,这是一种“有源”模型。它可正确地产生由同步电机本身派生的谐波分量。因此,它可用以研究源于电力元件的不对称或电力元件的非线性而出现的谐波潮流问题。
这一模型是双重解耦的,即其各序、各次谐波等值电路都相互解耦。因此,它们可分别与相应的电力网络模型联接。这一特点开辟了运用并行计算技术研究谐波潮流的道路。
简化的“无源”模型只能用以分析因电力元件非线性而出现的谐波潮流问题。即使如此,远离谐波源处的谐波电压、电流计算结果可能仍不能满足精度要求。
(责任编辑 丁玉瑜)
作者简介:龙禹(1973-),女,黑龙江人,东南大学硕士,现在南京供电局从事地区电力系统调度工作;
陈珩(1938-),男,东南大学教授,博士生导师,从事电力系统仿真、同步电机运行分析等研究。
龙禹(东南大学 电气工程系,江苏省 南京市 210096)
陈珩(东南大学 电气工程系,江苏省 南京市 210096)
参考文献:
[1] 张小平.同步电机谐波相量间的基本关系及其应用[j].中国电机工程学报, 1995, (15) 4: 110~117.
[2] 张小平.同步电机解耦-补偿谐波分析模型[j].电力系统自动化, 1995,(19)3:5~10.
[3] haskew t a,stern h p,chen z j.efficient dynamic synchronous machine simulation with harmonics[j].ieee trans on energy conversion,1986,11(2):298~304.
[4] cigre working group 36-05.harmonics, characteristic parameters, method of study, estimates of existing values in the network[j].electra, 1981, (77):35~54.
[5] ross t w,smith r m a.centralized ripple control on high voltage network[j].iee proc ⅱ,1948,95:470~479.
[6] clarke c d.discussion on reference[6].1973,iee publication 107:100.
[7] eggleston j f,arrillaga j,semley a.harmonic norton equivalent of the synchronous generator[j].journal of electrical and electronic engineering,1986,7(1):13~21.
[8] mahmoud a a,grady w m,mcgramaghan m f.power system harmonics[j].ieee tutorial course, 1984, ieee publications, new york, ny, 84eh0221-2-pwr.
[9] zhang x p,chen h.asymmetrical three-phase load-flow study based on symmetrical component theory[j].iee proc-gener transm distrib, 1994, 141(3):248~252.
[10] zhang x p,chu w j,chen h.decoupled asymmetrical three-phase load flow study by parallel processing[j].iee proc gener transm distrib, 1996,143(1):61~65.