a novel passive lossless snubber for
power inverter bridge legs
deng yan wu xie-hua he xiang-ning qian zhao-ming
(power electronics research institute of zhejiang university,hangzhou 310027,china)
abstract:this paper presents a novel passive snubber circuit suitable for inverter bridge leg modules. the optimized configuration is adopted in the main snubber circuit with the minimum number of additional components. being firstly transferred into a buffer capacitor, the snubber energy is recovered into the dc rail via a simple transformer based on the principle of resonant forward conversion. extra electrical stress on the main power switches is controllable and simple way's found as well solution for transformer-magnetic-reset-related high voltage problem across the clamping diodes. mathematical analysis, pspice simulation and experimental results confirm the effectiveness of the proposed snubber scheme.
key words:inverter; snubber; energy recovery; resonance▲
1 引言
现代电力电子技术的高频率、高功率密度趋势与硬开关工作方式所固有的严重开关损耗及电磁干扰(emi)问题之间的矛盾日益突出,一些开关功率器件本身工作原理要求严格限制开关时的du/dt和di/dt,另一些新型器件虽然可以不采用开关辅助手段或仅需简单措施即可正常工作,但从提高变换效率、器件利用率,增强电磁兼容性以及装置可靠性着眼,软开关技术对任何开关功率变换器都是有益的。在某些特殊情况(如有功率密度要求或散热条件限制场合)下尤为必要。从拓扑结构而言,传统的串电感和并电容的开关应力改善方法是唯一可能的无源软开关手段,由此发展而来的所谓无源软开关技术,实际上就是无损耗吸收技术。在无源与有源两大类软开关技术中,不使用额外开关元件、检测手段和控制策略的无源方式有着附加成本、可靠性、变换效率、性能价格比等诸多优势,在工业界单端变换器制造领域基本确立了主流地位,理论界近年来也逐渐认同了这一点[1,2]。就桥式逆变器而言,早期的耗能式吸收[3,4]只能以大的能量损耗为软开关代价,除一些很必要的情况(如门极可关断晶闸管,gto),一般都弱化吸收强度,仅起约束开关轨迹作用,不是真正意义的软开关技术;后来提出的部分馈能式[4]、无损耗[5,6]方案存在负载依赖性、工作频率范围、附加应力、网络复杂性等的问题,难以应用。同时,在开关功率器件模块化潮流下,可供放置吸收元件的空间余地越来越小,适于逆变桥模块的无损耗吸收技术更较少见诸文献。
文[1]是这一领域较新的结果,具有拓扑简明、适于模块工作、附加应力小等优点。其作者力图通过对吸收电路在图论上的性质研究得出其共性,进而获得普适性的吸收电路结构推导方法,在主吸收回路的简化理论上取得了一定的成果。但对一般的开关功率变换拓扑而言,并不存在太多的复杂性,从理论得出的最简吸收结构可以凭经验轻易得到,这削弱了理论的实际意义;当前无损耗吸收技术的关键已不是如何放置吸收储能元件,而是怎样处理吸收能量——在这方面[1]并未给出一般的原则以及适应于逆变桥的完善方法,所采用手段在网络简单的同时未能妥善兼顾回馈性能。无源无损耗吸收技术以主开关为吸收能量传递路径,若不能在单周期内完成上一开关状态变化所积累吸收能量的转移,就必然存在设计复杂、稳定工作过渡时间长、主开关过压波动及负载依赖性等缺陷。总的来看,逆变桥模块无源无损耗吸收技术因其特殊结构和难度而仍处在进一步研究和发展中。
2 电路结构
本文提出一种适用于逆变桥臂模块的无源无损耗吸收结构,如图1所示,为简单计,仅给出一相(单臂)电路。逆变桥上下两管可以共用吸收电感和吸收电容,其最简主吸收拓扑如图2所示,undeland电路[3]采用的是b型,本文采用a型。电压源变换器的无损耗吸收技术,关键在于构造一个无源电压源,用以吸纳、回馈吸收能量,复位吸收元件(在图2中表现为e)。一般的方法是以电容或互感器充当,本方案e存在于主管的关断吸收回路中,应尽可能接近纯容性,故不能直接使用变压器绕组,而以电容cb辅以能量回馈网络来替代。出于拓扑特殊性以及负载依赖性的考虑,大多数桥臂吸收电路都使用互感器回馈能量,由于磁通复位原因,普遍有副边二极管耐受数倍母线电压的要求,在一般为高输入电压的大功率场合,这是一个致命的问题,传统的缓解措施相当麻烦[5]。采用正激谐振变换的基本原理[8](如图3所示),利用变压器漏感,控制馈能变压器原边承受的励磁时间,这样可以简单增加一个线圈箝位副边二极管电压于2ud,同时确保磁通在主管关断后较快复位,其代价仅仅是主开关的短时间电流冲击和很小的(相对满载电流)磁化电流二极管续流损耗。

图1 新的电路结构
fig.1 the proposed snubber scheme

图2 两种最简桥臂吸收拓扑
fig.2 two basic optimized snubber
configurations for bridge legs

图3 馈能变压器工作原理
fig.3 equivalent circuit of the energy recover transformer
3 工作原理分析
3.1 符号、用语定义
参照图1,ud为电源电压;iload为负载电流;im为最大负载电流;fs为开关频率;u1为sp关断期间cb最大电压;upk为主开关最大过电压;ipk为主管最大冲击电流;n为互感器副边与原边匝比;lk为变压器原边等效串联电感(漏感);tdd为死区时间;tlost为一周期内吸收电路瞬态过程占用时间。
3.2 上管开关过程
等效电路变换如图4所示。分析以各状态开始为时间坐标零点。
状态a dn续流;
状态b 上管开通,直至dn续流结束为止,其间ls承担电源电压,实现sp的零电流开通和dn反向恢复di/dt的抑制,cb开始通过sp放电,
icb(t)=δuz1-1sinω1t (1)
式中 δu=(u1-udn-1);ω1=(lkcb)-1/2;
z1=(lkcb-1)1/2, 忽略二极管反向恢复时间,本状态持续时间为


图4 上管开关过程
fig.4 snubber commutation of the upper switch
tb=lsiloadu-1d (2)
状态c dn恢复阻断,cs通过sp放电,cb继续放电
ils(t)=iload+udz2-1sinω2t (3)
ucs(t)=udcosω2t (4)
icb(t)=δuz1-1 sin[ω1(t+tb)] (5)
tc<π/ω2 (6)
式中 z2=(lscs-1)1/2, ω2=(lscs)-1/2;tc为状态持续时间
状态d 开始于cs放电到下正上负且电压幅值与cb一致时,此后ls、cb、cs、lk及变压器原边之间进行相互作用,这是一个高阶谐振过程,可以求得其解析表达式如下:
ucb(t)=(ls+lk)-1lsudn-1(1-cosωt)+
uccos ωt+(is-ik)zsin ωt (7)
ils(t)=is-lk(ls+lk)-1(is-ik)(1-cos ωt)-
udn-1(ls+lk)-1(t-ω-1sinωt)-
uc ω-1lssin ωt (8)
式中 ω=[lslk(cb+cs)(ls+lk)-1]-1/2;z=[lslk(ls+lk)-1(cs+cb)-1]1/2,is、ik、uc分别是d过程ls、lk及cs和cb的初始电流电压,正方向如(d)图所示,当ls电流回复iload,d结束。由式(8)可见,吸收电感电流含周期变化部分和线性下降的分量,可确保复位,且当
(1+m)3m-1<π2(1+n) (9)
时,ls电流可于
td<π/ω (10)
之内回复至负载电流,其中m=lk/ls,n=cb/cs。此时cb上电压如果不小于2ud/n,即可确保cb、cs存储能量无条件通过变压器完全释放,由式(5)能够得出其充分条件
n>;3{[4k2u+3sin arc cos2(kun-1)]1/2-ku}-1z (11)
以及
m>;[-2bn-1+a(a2+b2-4n-2)1/2]-2.(a2+b2)2-1 (12)
其中a=n-1/2sin arc cosku,b=δu/ud,ku=u1/ud;
状态e 开始于ls电流回复到iload,cs、cb中残余能量通过变压器原边回馈到电源,在电容电压降至零后,上管开通过程结束进入导通稳态f,变压器原边剩余较小的磁化电流经主管、da2续流,e持续时间
te<π/2ω1+(nupk/ud-1)lksin arc cos[ud/(nupk-ud)]/z1 (13)
状态g 从上管的关断开始,负载电流由cb、ds1旁路,实现零电压关断,变压器磁化电流改由经cs,副边箝位线圈导通开始其磁通复位;当负载电流较大时,cs电压上升快,若在下管开通信号给出前已经达到ud,则g直接转为状态h,然后至状态j,即回到初态a,否则,在死区时间tdd后,sn导通,g经i过渡到h、j,
u1=max{imz3,udz3/z2} (14)
式中 z3=(ls/cb)1/2。
3.3 下管开关过程
等效电路变换与上管情况类似。本拓扑作用于上下两管的过程是不完全对称而又相当类似的。所存在的差异多表现在量值上,u1在sp正向载流时随负载情况变化,在sn正向载流时则恒定于u1=udz3/z2;sn仅在正向载流开通时承受cs充电电流,区别于sp无论正向载流还是反并二极管载流均需在开通时承担cs和cb的放电电流,附加电流应力大于前者;三阶谐振的初始条件也不尽相同,如ls与负载电流源并联参与谐振,其初值电流最大值i1在上管正向载流时相对稳定在
i1=ud/z2 (1~sinarccosku) (15)
在u1=ud/3时这一范围为±3%,在下管工作时则随负载变化于
i1=max{ud/z2,im/kt} (16)
式中 kt=tddim/(csud)。原理性拓扑基本没有差别,主要解析式通用,分析可参照上管,在此不再赘述。
4 参数选取与估算
对于无源无损耗吸收电路而言,最关心的是怎样设定参数而确保性能指标,其中比较重要的有:主开关的附加应力(电流过冲、过电压),馈能网络的工作(复位)速度(关系到实现软开关的占空比限制和适用频率范围)以及负载依赖性等。由于这一拓扑有高阶谐振工作过程,还根据不同工况随初始条件变动,一些参数获取需求解超越方程,解析解不易获取,而工程上只需给出较大余量的设计取值范围,以保证满足某些条件即可。以下依次进行估算,结果均为达到相应要求所需的充分条件。
主管电流峰值出现在满负荷时sp承载cs、cb放电电流期间,从式(3)(5)可见,
据此可以选取合适的lk以加大z1削减过冲,在允许温升范围内,一般功率器件都有较强的瞬时电流过载能力,最弱的mosfet也可承受4倍以上额定电流的短时间冲击,故并不要求严格限制。主管峰值电压发生于sp开通后由ls对cb进行再充电过程中,可按下式求取
upk<(u12+i12z32)1/2 (18)
由此可选取适当的cb值以控制过电压。
将式(2)、(6)、(10)、(13)相加,可以容易地求得最大占空比损失时间
tlost=tb+tc+td+te (19)
本文在300v,10a,20khz的逆变装置上进行实验和仿真,希望电路主开关电流冲击不超过3倍,电压冲击不超过50%,占空比损失不超过20%。考虑上下管关断吸收的对称性,cb应当远大于cs,取n=10,则cb=330nf,使用试探的方法,首先确保式(9)、(11)、(12)的要求,再计算上述指标,得到一组参数为ud=330v,im=10a,fs=20khz,ls=20μh,cs=33nf,lk5μh,n=8。由式(17)可求得ipk<35a,由式(14)、(16)、(18)得到upk<134v。又由式(19)、(13)、(10)、(6)、(2)可计算得到tlost<11.4μs(均为大余量估算)。这些结果基本符合我们对吸收电路指标的要求。
5 仿真与实验结果
仿真结果如图5所示,实验波形在图6中给出,其中电源电压由于其内阻压降而略微不足300v。从上述结果看到,二者一致性相当好,电路效果良好。


满载电流10a,轻载电流1a,每组从上到下分别为:开通细节, 关断细节,主管电流与变压器能量回馈电流
图5 仿真波形
fig.5 simulated waveforms
ipk≤im+ud/z2+δu/z1sinω1[lsim/ud+
(π/2+arcsinku)/ω2] (17)
6 结论
本文提出的这种适用于逆变桥臂模块无源无损耗吸收电路,具有拓扑简单、性能良好、附加稳态应力受控等优点。在全桥逆变的情况下,二桥臂可共用同一缓冲电感及能量转移电容和吸收能量回馈网络,附加成本进一步降低。这一新型无源无损耗吸收电路具有良好的工程实用性。

图6 实验波形
fig.6 experimental waveforms
基金项目:浙江省自然科学基金青年科技人才专项资金(rc98030)。
作者简历:邓焰(1973-),男,四川宜宾人,博士,助教,从事功率变换器拓扑研究;
吴燮华(1945-),女,副教授,从事电力电子技术及其工业应用研究;
何湘宁(1961-),男,湖南长沙人,博士,教授,博导,ieee高级会员,常务副
所长,从事电力电子技术及其工业应用方面的研究和工程设计工作,在国内外发表
论文80余篇;
钱照明(1939-),男,江苏扬州人,教授,博导,ieee高级会员,研究领域为现代
电力电子器件及其相关技术,特种工业电源及电力电子系统电磁兼容等。
作者单位:邓焰(浙江大学电力电子技术研究所,浙江省 杭州市 310027)
吴燮华(浙江大学电力电子技术研究所,浙江省 杭州市 310027)
何湘宁(浙江大学电力电子技术研究所,浙江省 杭州市 310027)
钱照明(浙江大学电力电子技术研究所,浙江省 杭州市 310027)
参考文献:
[1]smith k m,smedley k m.lossless passive soft switching methods for inverters and amplifiers[j].ieee pesc'97:1431~1439.
[2]tseng ching-jung,chen chern-lin.passive lossless snubbers for dc/dc converters[j].ieee apec'98:1049~1054.
[3]undeland t,jenset f,steinbakk a,et al.a snubber configuration for both power transistor and gto pwm inverters[j].ieee pesc'84:42~53.
[4]mcmurray w.efficient snubber configuration for voltage souce gto inverters[j].ieee pesc'85:20~27.
[5]holtz j,salama s,werner k h,et al.a nondissipative snubber circuit for high-power gto inverters[j].ieee trans on ia,1989,25(6):620~626.
[6]williams b w.high-voltage high-frequency power-switching transistor module with switching-aid-circuit energy recovery[j].iee proc.1984,131(1):7~12.
[7]perez m a,sebastian j,diaz j,et al.the forward discharge converter (fdc):a general solution to obtain soft-switching in any power converter[j].ieee pesc,1992:101~108.

更多